– The Pilots ACVP-H are used as constant pressure regulators, mounted directly over main valves AM1 or AM3 but can be also mounted on a housing valve CVH in a
external line to control one or more AM or RAK valves.
– The Pilots ACVP-H working in higher pressure with a range of 4 Bars to 25 Bars.
– Turning the regulating spindle clockwise to increase the opening pressure of the pilot, (thus the condensating pressure and temperature),and they decrease when we turn the spindle anticlockwise.
– ACVP-H pilot valve is used to keep AM main valve inlet pressure constant. It can also be used as a safety valve. For example, to prevent excessive pressure due to the
presence of effusion.
– Must use stainless steel bolts when it is used at ambient temperature below-50C.